sat, 13-mar-2010, 16:58

New pump

New water pump

Spent much of the day today getting parts and replacing our water pump. The old one wasn’t drawing water out of the tank very well, didn’t show pressure on the gauge, and couldn’t be primed without taking it off of the pressure tank. Earlier in the week we had a brief freeze-up of our supply line and I decided it was the last time I was going to drag the old pump off the pressure tank just so I could prime it.

The new pump is a Myers pump, Made in the U.S.A., and seems to be a little quieter than the old one. While I was doing it, I replaced a few more of the plastic compression fittings in the mechanical room with crimp-style fittings. The plastic ones are no longer sold because they eventually leak.

One remaining issue is getting the pressure tank and the pressure switch working well together. When I first hooked it up, I lowered the pressure tank to 18 psi (2 pounds lower than the low setting the switch is supposed to default to), and the pump starting rapidly switching itself on and off again. I tried lowering the pressure in the pressure tank until there was nothing left in it, and then started looking at the new gauge. Turns out the new switch was set to something like 15–30 instead of 20–40. After I filled the pressure tank back to 18 psi and adjusted the pressure switch to 24–35, everything works without the on-off-on-off problems. I’d like it to be closer to 20–40, but that will take some fine tuning of the pressure switch.

tags: house  pump  water 